LOUDSPEAKER OUTPUT
A two-watt, 8-ohm audio output is provided at Speaker terminals, J13. The top terminal is ground, the bottom terminal is signal. The output level is controlled by the Vol control, R24. A remote
volume control can be connected to the Vol terminals, J14. These terminals are currently jumpered. An internal loudspeaker is currently connected to the speaker terminals to allow you to hear your signals. If this
output is used, the internal loudspeaker should be disconnected.
RELAY OUTPUT
A normally open relay contact is provided at Key Relay terminals, J7. This relay contact, rated at .25 amp @ 24VDC, closes whenever there is an alarm and remains closed for the duration of the
alarm. This output is often used to activate equipment by others.
The features of the RA-500 encoder are programmable. If you have any questions, or need any further assistance, please contact CDT.
|